Artikel nûmer | 6ES7222-1BF32-0XB0 | 6ES7222-1BH32-0XB0 | 6ES7222-1BH32-1XB0 | 6ES7222-1HF32-0XB0 | 6ES7222-1HH32-0XB0 | 6ES7222-1XF32-0XB0 |
| Digitale Utfier SM1222, 8 DO, 24V DC | Digitale Utfier SM1222, 16 DO, 24V DC | Digitale Utfier SM1222, 16DO, 24V DC sink | Digitale Utfier SM 1222, 8 DO, Relay | Digitale Utfier SM1222, 16 DO, Relay | Digitale Utfier SM 1222, 8 DO, Wizigje |
Algemiene ynformaasje | | | | | | |
Produkt type oantsjutting | SM 1222, DQ 8x24 V DC/0,5 A | SM 1222, DQ 16x24 V DC/0,5 A | SM 1222, DO 16x 24 V DC / 0,5 A Sink | SM 1222, DQ 8x relais/2 A | SM 1222, DQ 16x relais/2 A | SM 1222, DQ 8x relais/2 A |
Supply voltage | | | | | | |
tastien berik, legere limyt (DC) | 20,4 V | 20,4 V | 20,4 V | 20,4 V | 20,4 V | 20,4 V |
tastien berik, boppegrins (DC) | 28.8 V | 28.8 V | 28.8 V | 28.8 V | 28.8 V | 28.8 V |
Ynputstroom | | | | | | |
út backplane bus 5 V DC, max. | 120 mA | 140 mA | 140 mA | 120 mA | 135 mA | 140 mA |
Digitale útgongen | | | | | | |
● út load spanning L+, max. | | | | 11 mA/relay coil | 11 mA/relay coil | 16,7 mA / relay coil |
Power ferlies | | | | | | |
Power ferlies, typ. | 1.5 W | 2,5 W | 2,5 W | 4,5 W | 8,5 W | 5 W |
Digitale útgongen | | | | | | |
Oantal digitale útgongen | 8 | 16 | 16 | 8 | 16 | 8 |
● yn groepen fan | 1 | 1 | 1 | 2 | 1 | 1 |
Strom-sinking | | | Ja | | | |
Koarte-circuit beskerming | Nee; ekstern te foarsjen | Nee; ekstern te foarsjen | Nee; ekstern te foarsjen | Nee; ekstern te foarsjen | Nee; ekstern te foarsjen | Nee; ekstern te foarsjen |
Beheining fan inductive shutdown voltage oan | typ. (L+) -48 V | typ. (L+) -48 V | Typ 45 V | | | |
Switching kapasiteit fan de útgongen | | | | | | |
● mei resistive lading, max. | 0,5 A | 0,5 A | 0,5 A | 2 A | 2 A | 2 A |
● op lampelast, max. | 5 W | 5 W | 5 W | 30 W mei DC, 200 W mei AC | 30 W mei DC, 200 W mei AC | 30 W mei DC, 200 W mei AC |
Output voltage | | | | | | |
● Rated wearde (DC) | 24 V | 24 V | 24 V | 5 V DC oant 30 V DC | 5 V DC oant 30 V DC | 5 V DC oant 30 V DC |
● Rated wearde (AC) | | | | 5 V AC oan 250 V AC | 5 V AC oan 250 V AC | 5 V AC oan 250 V AC |
● foar sinjaal "0", max. | 0,1 V; mei 10 kOhm lading | 0,1 V; mei 10 kOhm lading | L+ minus 0,75 V DC mei 10k Load | | | |
● foar sinjaal "1", min. | 20 V DC | 20 V DC | 0,5 V | | | |
Output hjoeddeistige | | | | | | |
● foar sinjaal "1" rated wearde | 0,5 A | 0,5 A | 0,5 A | 2 A | 2 A | 2 A |
● foar sinjaal "0" reststrom, max. | 10 µA | 10 µA | 75 µA | | | |
Utfierfertraging mei resistive load | | | | | | |
● "0" oant "1", max. | 50 µs | 50 µs | 20 µs | 10 ms | 10 ms | 10 ms |
● "1" oant "0", max. | 200 µs | 200 µs | 350 µs | 10 ms | 10 ms | 10 ms |
Totale stroom fan de útgongen (per groep) | | | | | | |
horizontale ynstallaasje | | | | | | |
- oant 50 °C, max. | 4 A; Strom per massa | 8 A; Strom per massa | 8 A; Strom per massa | 10 A; Strom per massa | 10 A; Strom per massa | 2 A; Strom per massa |
Relay útgongen | | | | | | |
● Oantal estafette útgongen | | | | 8 | 16 | 8 |
● Nominearre oanbodspanning fan relaisspoel L+ (DC) | | | | 24 V | 24 V | 24 V |
● Oantal operaasjesyklusen, max. | | | | meganysk 10 miljoen, by rated load spanning 100 000 | meganysk 10 miljoen, by rated load spanning 100 000 | meganysk 10 miljoen, by rated load spanning 100 000 |
Switching kapasiteit fan kontakten | | | | | | |
- mei induktive load, max. | 0,5 A | 0,5 A | 0,5 A | 2 A | 2 A | 2 A |
- op lampelast, max. | 5 W | 5 W | 5 W | 30 W mei DC, 200 W mei AC | 30 W mei DC, 200 W mei AC | 30 W mei DC, 200 W mei AC |
- mei resistive load, max. | 0,5 A | 0,5 A | 0,5 A | 2 A | 2 A | 2 A |
Kabel lingte | | | | | | |
● shielded, max. | 500 m | 500 m | 500 m | 500 m | 500 m | 500 m |
● unshielded, max. | 150 m | 150 m | 150 m | 150 m | 150 m | 150 m |
Underbrekt / diagnoaze / statusynformaasje | | | | | | |
Alarms | | | | | | |
● Diagnostic alarm | Ja | Ja | Ja | Ja | Ja | Ja |
Diagnoaze yndikaasje LED | | | | | | |
● foar status fan de útgongen | Ja | Ja | Ja | Ja | Ja | Ja |
Potinsjele skieding | | | | | | |
Potinsjele skieding digitale útgongen | | | | | | |
● tusken de kanalen | | | | Relays | Relays | Relays |
● tusken de kanalen, yn groepen fan | 1 | 1 | 1 | 2 | 4 | 1 |
● tusken de kanalen en backplane bus | 500 V AC | 500 V AC | 500 V AC | 1 500 V AC foar 1 minút | 1 500 V AC foar 1 minút | 1 500 V AC foar 1 minút |
Talitten potinsjele ferskil | | | | | | |
tusken ferskillende circuits | | | | 750 V AC foar 1 minút | 750 V AC foar 1 minút | 750 V AC foar 1 minút |
Grade en klasse fan beskerming | | | | | | |
IP graad fan beskerming | IP20 | IP20 | IP20 | IP20 | IP20 | IP20 |